Electronics Technician (Fire Alarm Systems)
This listing is for an Electronics Technician (Fire Alarm Systems) role at Centers for Disease Control and Prevention, in Atlanta, Georgia, United States. It is listed as a full-time position.
DGJ summary of this job
Our own short read of this listing, built only from the facts it gives. The employer’s original text follows further down.
This listing is for an Electronics Technician (Fire Alarm Systems) role at Centers for Disease Control and Prevention, in Atlanta, Georgia, United States. It is listed as a full-time position.
The listing gives the pay as $94,654 - $123,052 per year.
The advert does not mention visa sponsorship. If you would move to United States for this job, check the official work permit route first (DGJ Insight lists it where we have it).
Dev Global Jobs found this job on USAJobs on Nov 19, 2026; applications close on Nov 25, 2026.
- Employer
- Centers for Disease Control and Prevention
- Location
- Atlanta, Georgia, United States
- Job type
- Full-time
- Pay
- $94,654 - $123,052 per year
- Found
- Nov 19, 2026 on USAJobs
- Closes
- Nov 25, 2026
- Employer text
- 708 words, about 3 min to read
- Apply only on the official page (usajobs.gov). Dev Global Jobs is not the employer and never asks for a fee.
- Plan to apply before Nov 25, 2026.
- Read the employer’s full text below (about 3 min) before you apply.
- Build or check your CV with the free DGJ CV Builder.
DGJ Insight
Our own data about this role and place, from official statistics and our live job index.
This job's listed pay is 25% above the benchmark.
Source: OECD Average annual wages, 2025
- H-1B specialty occupation: Employer petition, bachelor's degree or higher in the specialty; annual cap and lottery
- L-1 intracompany transferee: Employees of a related company abroad transferring to a US office
- O-1 extraordinary ability: Evidence of extraordinary ability in sciences, arts, education, business or athletics
Official routes: USCIS
About the role
Full text from the employer, as published on USAJobs, arranged into sections. Nothing added or removed.
WHAT WE ARE LOOKING FOR Minimum Qualifications: You must have one year specialized experience to perform successfully the duties of the position. To be creditable, specialized experience must have been equivalent to at least the GS-11 grade level in the Federal service performing ALL of the following: Operating, maintaining, testing, and troubleshooting electronic fire alarm and fire suppression systems in accordance with applicable fire protection codes and standards.
Inspecting and evaluating fire alarm and fire suppression systems to ensure compliance with National Fire Protections Association requirements and identify corrective actions. Providing technical guidance on the installation, maintenance, or modification of electronic life safety systems supporting facility operations. Supervising technical personnel responsible for maintaining electronic fire alarm and fire suppression systems in a complex facilities environment.
Documenting experience: IN DESCRIBING YOUR EXPERIENCE, PLEASE BE CLEAR AND SPECIFIC. WE WILL NOT MAKE ASSUMPTIONS REGARDING YOUR EXPERIENCE. Qualifications are based on breadth/level of experience. In addition to describing duties performed, applicants must provide the exact dates of each period of employment (from MM/YY to MM/YY) and the number of hours worked per week if part time.
As qualification determinations cannot be made when resumes do not include the required information, failure to provide this information may result in disqualification. Applicants are encouraged to use the USAJOBS Resume Builder to develop their federal resume. Do not copy and paste the duties, specialized experience, or occupational application questionnaire from this announcement into your resume as that will not be considered a demonstration of your qualifications for this position.
In accordance with Office of Personnel Management policy, federal employees are assumed to have gained experience by performing duties and responsibilities appropriate for their official series and grade level as described in their position description.
Experience that would not normally be part of the employee's position is creditable, however, when documented by satisfactory evidence, such as a signed memorandum from the employee's supervisor or an SF-50 or SF-52 documenting an official detail or other official assignment. The documentation must indicate whether the duties were performed full time or, if part time, the "percentage of times" the other duties were performed.
It is expected that this documentation is included in the employee's official personnel record. In order to receive credit for experience in your resume that is not within the official series and grade level of your official position, you must provide a copy of the appropriate documentation of such experience as indicated above.
Experience refers to paid and unpaid experience, including volunteer work done through national Service programs (e.g., Peace Corps, AmeriCorps) and other organizations (e.g., professional; philanthropic; religious; community; student; social). Volunteer work helps build critical competencies, knowledge, and skills and can provide valuable training and experience that translates directly to gain employment. You will receive credit for all qualifying experience, including volunteer experience.
If such experience is on a part-time basis, you must provide the average number of hours worked per week as well as the beginning and ending dates of the experience so it can be fully credited. OPM Qualification General Policies Website
WHAT YOU'LL BE DOING DAY TO DAY As an Electronic Technician (Fire Alarms Systems), you will use your knowledge and experience to optimize business results and customer experience by: Supervise fire alarm systems operations and maintenance activities by directing staff, assigning work, establishing priorities, evaluating performance, and ensuring compliance with safety, operational, and personnel requirements.
Manage the operation, maintenance, testing, and programming of fire alarm and fire suppression systems to ensure compliance with NFPA codes, CDC standards, and applicable regulatory requirements across assigned facilities. Inspect and evaluate fire alarm and fire suppression systems by assessing system performance, recommending upgrades or replacements, supporting construction and renovation projects, and verifying code compliance.
Provide technical leadership on fire protection systems by resolving complex technical issues, coordinating with engineers, contractors, and maintenance personnel, and ensuring reliable life safety system performance. Assist engineering personnel in modifying or drafting Standard Operating Procedures to meet changing needs relative to operation or maintenance.
This position has 20% supervisory duties, candidates must also have demonstrated or shown the potential to develop the necessary knowledge, skills, and abilities. Applicants should describe any previous experience or responsibilities which could be used in relation to the supervisory requirements of this position.
Ask CSI about this job
Answers link to jobs and tools on Dev Global Jobs.
Review Dev Global Jobs
Used this site to find a job? Tell other job seekers what worked and what did not.